title: "QUIC and ECS as Complementary Transport and Runtime Substrates
|
|
for Industrial Digital Twins: An Integrated Empirical Study"
|
|
title-running: "QUIC+ECS for Industrial Digital Twins"
|
|
author-running: "Plantevin"
|
|
|
|
author: "Valère Plantevin\\inst{1}\\orcidID{0000-0000-0000-0000}"
|
|
institute: "Département d'informatique et de mathématiques, Université du Québec à Chicoutimi (UQAC), Chicoutimi, Canada \\email{vplantev@uqac.ca}"
|
|
|
|
abstract: |
|
|
Industrial Digital Twin runtimes face a dual challenge: efficient
|
|
in-process state management across heterogeneous asset populations, and
|
|
low-latency transport of heterogeneous sensor streams with differing
|
|
reliability requirements. We argue that these two challenges admit
|
|
complementary structural solutions. The Entity-Component-System (ECS)
|
|
architectural pattern constitutes a natural runtime substrate, providing
|
|
cache-coherent bulk state updates, $O(k)$ archetype mutation for asset
|
|
lifecycle events, and DAG-driven parallel system scheduling. QUIC's
|
|
mixed-reliability multiplexing constitutes a natural transport substrate,
|
|
mapping three DT sensor data tiers onto unreliable datagrams, unidirectional
|
|
streams, and bidirectional streams respectively. We integrate both substrates
|
|
into a single prototype and validate the combined system on an industrial
|
|
Raspberry Pi CM5 (Cortex-A76) receiving real QUIC traffic from a dedicated
|
|
traffic generator. An empirical sweep across 50k--200k asset instances and
|
|
0--5\% packet loss confirms that the ECS tick rate remains an order of
|
|
magnitude above the cadence required for industrial DT operation under all
|
|
tested conditions, that cross-tier head-of-line blocking isolation holds
|
|
end-to-end -- the lossy datagram tier surfaces no measurable loss-induced
|
|
latency while the reliable bidirectional tier absorbs the expected QUIC
|
|
retransmit cost -- and that memory scales linearly at less than $0.2$~MB
|
|
per 1,000 entities on target edge hardware. Finally, the prototype functions as an active edge controller rather
|
|
than a passive telemetry pipeline, executing end-to-end closed-loop actuation
|
|
triggered directly from a standard Grafana observability dashboard.
|
|
|
|
keywords:
|
|
- digital twin
|
|
- entity-component-system
|
|
- QUIC
|
|
- industrial IoT
|
|
- real-time transport
|
|
- edge computing
|
|
|
|
bibliography: references.bib
|
|
---
|
|
|
|
```{python}
|
|
#| label: setup
|
|
#| include: false
|
|
import pandas as pd
|
|
import matplotlib.pyplot as plt
|
|
import matplotlib.ticker as mticker
|
|
import numpy as np
|
|
from pathlib import Path
|
|
|
|
# Paths relative to paper/
|
|
DATA_TWO_MACHINE = Path("../data/two_machine")
|
|
FIGURES = Path("figures")
|
|
FIGURES.mkdir(exist_ok=True)
|
|
|
|
# Load sweep CSVs when they exist; provide empty defaults otherwise
|
|
def load_csv(path: Path) -> pd.DataFrame:
|
|
if path.exists():
|
|
return pd.read_csv(path)
|
|
return pd.DataFrame()
|
|
|
|
# CM5 sweep (M4 Max generator → CM5 substrate, 1 Gbps direct Ethernet).
|
|
# Holds T1 P99, T3 RTT P99, per-entity-count throughput / RSS.
|
|
# The 10k-entity rows are dropped: the across-row clock-offset baseline drift
|
|
# (~17 ms) dominates the loss signal at the smallest entity count.
|
|
df_sweep = load_csv(DATA_TWO_MACHINE / "final_table.csv")
|
|
if len(df_sweep):
|
|
df_sweep = df_sweep.query("entities >= 50000").reset_index(drop=True)
|
|
df_latency = df_sweep
|
|
df_throughput = df_sweep
|
|
|
|
# Per-cell value lookups for the result tables.
|
|
def _t1(e, l): return float(df_latency.query(f"entities=={e} and loss_pct=={l}")["t1_p99_us"].iloc[0]) / 1000.0
|
|
def _t3(e, l): return float(df_latency.query(f"entities=={e} and loss_pct=={l}")["t3_rtt_us"].iloc[0]) / 1000.0
|
|
def _hz(e, l): return int(round(float(df_throughput.query(f"entities=={e} and loss_pct=={l}")["hz"].iloc[0])))
|
|
def _rss(e): return float(df_throughput.query(f"entities=={e}")["rss_mb"].mean())
|
|
|
|
# Key scalars used inline in the prose.
|
|
hz_at_100k_0pct = _hz(100000, 0)
|
|
hz_at_100k_5pct = _hz(100000, 5)
|
|
rss_at_100k = float(
|
|
df_throughput.query("entities == 100000 and loss_pct == 0")["rss_mb"].iloc[0]
|
|
)
|
|
|
|
# Memory R² — linear regression of mean RSS vs entity count on the CM5 sweep.
|
|
_rss_by_n = df_throughput.groupby("entities")["rss_mb"].mean().sort_index()
|
|
_x = _rss_by_n.index.values.astype(float)
|
|
_y = _rss_by_n.values.astype(float)
|
|
r2_memory = float(np.corrcoef(_x, _y)[0, 1] ** 2)
|
|
# MB per 1k entities, slope of the linear fit
|
|
_slope_mb_per_entity, _intercept = np.polyfit(_x, _y, 1)
|
|
mb_per_1k = float(_slope_mb_per_entity * 1000.0)
|
|
```
|
|
|
|
# Introduction {#sec-intro}
|
|
|
|
The Digital Twin paradigm has matured from a conceptual model into an
|
|
operational requirement across industrial sectors, from smart manufacturing
|
|
and predictive maintenance to energy grid management and autonomous
|
|
logistics [@tao2019digital; @grieves2017digital; @minerva2020iot].
|
|
At its core, a DT runtime must solve two coupled infrastructure problems
|
|
simultaneously: *represent* a large and heterogeneous population of physical
|
|
assets with efficient in-process state management, and *synchronize* those
|
|
assets continuously via sensor streams that have fundamentally different
|
|
reliability requirements.
|
|
|
|
These problems are typically addressed separately. Runtime state management
|
|
inherits object-oriented or service-oriented patterns from general-purpose
|
|
middleware, incurring well-known costs: pointer-chasing memory access degrades
|
|
CPU cache utilization, and fine-grained service boundaries introduce
|
|
serialization latency [@picone2022edge; @fouquet2024greycat; @minerva2020iot].
|
|
Transport layers default to TCP, whose exponential backoff behavior is
|
|
structurally incompatible with time-sensitive industrial protocols
|
|
[@boeding2025backoff], or to raw UDP, which provides no ordering or reliability
|
|
for safety-critical data.
|
|
|
|
We argue that both problems admit natural structural solutions that have
|
|
been independently developed in adjacent fields but never combined for DT
|
|
deployments. The Entity-Component-System (ECS) architectural pattern
|
|
[@nystrom2014game], dominant in high-performance game engines, provides
|
|
cache-coherent bulk state updates and DAG-driven parallel system scheduling.
|
|
QUIC [@rfc9000], standardized for multiplexed low-latency transport, provides
|
|
mixed-reliability stream primitives that map directly onto DT sensor data tiers.
|
|
|
|
Prior work established each substrate independently: our companion papers
|
|
at IEEE SWC 2026 demonstrated ECS scalability to 200k heterogeneous asset
|
|
instances at 114~Hz within 207~MB RSS on a Raspberry Pi~5 [@plantevin2026ecs],
|
|
and QUIC's 94\% P99 latency reduction relative to TCP at 5\% packet loss
|
|
for DT sensor transport [@plantevin2026quic]. The present paper asks: do they
|
|
compose? Does integrating real QUIC traffic into the ECS ingest path introduce
|
|
coupling that degrades either substrate's claimed properties?
|
|
|
|
This paper makes three primary contributions. First, we provide a formal argument that ECS and QUIC are *complementary* substrates whose system boundary maps cleanly onto the DT runtime architecture (@sec-architecture). Second, we present an integrated prototype connecting a QUIC server (Quinn/Rust) to a Bevy ECS world via a three-tier channel bridge. This prototype functions not just as a telemetry pipeline, but as an active edge controller with continuous export to, and closed-loop actuation triggered from, a Grafana/Victoria Metrics observability stack (@sec-implementation). Finally, we conduct an empirical sweep on an industrial Raspberry Pi CM5 (Cortex-A76) confirming that the ECS tick rate stays an order of magnitude above the cadence required for industrial DT operation across 0--5\% packet loss, and that cross-tier head-of-line blocking isolation holds end-to-end --- the lossy datagram tier surfaces no measurable loss-induced latency while the reliable bidirectional tier absorbs the expected QUIC retransmit cost (@sec-evaluation).
|
|
|
|
# Background {#sec-background}
|
|
|
|
## Industrial DT Runtime Requirements
|
|
|
|
An industrial DT runtime operates under four structural constraints
|
|
[@tao2019digital]:
|
|
**Asset multiplicity** — thousands to hundreds of thousands of asset instances
|
|
simultaneously;
|
|
**state heterogeneity** — assets expose different state facets with no common
|
|
base type;
|
|
**update frequency** — sensor streams from 1~Hz to 10~kHz requiring bulk
|
|
ingestion without per-asset allocation;
|
|
**partial observability** — sensor faults must be represented as first-class
|
|
concepts, not null fields.
|
|
|
|
## ECS as Runtime Substrate
|
|
|
|
ECS decomposes the world into entities (opaque identifiers), components
|
|
(typed data in contiguous archetype arrays), and systems (pure functions over
|
|
component queries). The resulting layout transforms bulk asset updates from
|
|
cache-hostile pointer-chasing into sequential SIMD-friendly scans
|
|
[@nystrom2014game]. Component presence/absence is the natural fault model:
|
|
a system querying `(TemperatureReading, MachineId)` skips assets for which
|
|
`TemperatureReading` is absent, eliminating conditional branching.
|
|
|
|
## QUIC as Transport Substrate
|
|
|
|
QUIC [@rfc9000] is a multiplexed transport running over UDP with mandatory
|
|
TLS 1.3. Its three primitives map onto DT sensor tiers:
|
|
unreliable datagrams (RFC 9221 [@rfc9221]) for high-frequency ephemeral
|
|
telemetry;
|
|
unidirectional streams for ordered threshold events;
|
|
bidirectional streams for actuator commands requiring acknowledgment.
|
|
Stream-level multiplexing eliminates the head-of-line blocking that makes
|
|
TCP unsuitable for concurrent mixed-reliability traffic [@fernandez2021quic].
|
|
|
|
# Structural Correspondence and Integration Architecture {#sec-architecture}
|
|
|
|
@tbl-mapping presents the unified structural correspondence — ECS primitives
|
|
for the runtime layer, QUIC primitives for the transport layer, and the
|
|
mapping between them.
|
|
|
|
| DT Concept | ECS Primitive | QUIC Primitive |
|
|
|---|---|---|
|
|
| Asset instance | Entity | — |
|
|
| State facet | Component (archetype) | — |
|
|
| Behavioral model | System (pure function) | — |
|
|
| Sensor fault | Component absence | — |
|
|
| Ephemeral telemetry (T1) | `RawSensorData` write | Unreliable datagram |
|
|
| Threshold event (T2) | `AlertEvent` insert | Unidirectional stream |
|
|
| Actuator command (T3) | `OutboundT3` enqueue + ack | Bidirectional stream (server-initiated) |
|
|
| Shadow export | Read-only system query | Victoria Metrics write |
|
|
|
|
: Unified structural correspondence: DT concepts, ECS primitives, and QUIC primitives. {#tbl-mapping}
|
|
|
|
The system boundary is a **three-tier channel bridge**: a Tokio async runtime
|
|
hosts the Quinn QUIC server; bounded MPSC channels carry T1 datagrams and T2
|
|
uni-stream events from the network side into the ECS, while a separate
|
|
outbound channel carries T3 actuator setpoints from the ECS back out to the
|
|
relevant device. T1 is lossy (dropped under backpressure); T2 applies
|
|
asynchronous backpressure on the inbound channel; T3 is substrate-initiated
|
|
and uses a per-device connection registry to open a fresh bidirectional
|
|
stream per actuator command. Bevy's `IngestSystem` drains the two inbound
|
|
channels at the start of each tick. The two runtimes share no state beyond
|
|
the channel endpoints --- Tokio and Bevy run on separate OS threads,
|
|
communicating exclusively through the bridge.
|
|
|
|
This separation is architecturally significant: QUIC head-of-line blocking
|
|
isolation and ECS system scheduling isolation are orthogonal and additive.
|
|
Under packet loss, the lossy T1 tier should absorb drops silently with no
|
|
surfaced latency, while the reliable T3 tier should expose the QUIC
|
|
retransmit cost as added round-trip time --- without either bleeding into
|
|
the ECS tick schedule. @sec-evaluation tests this claim empirically.
|
|
|
|
# Implementation {#sec-implementation}
|
|
|
|
## Integrated Prototype
|
|
|
|
The prototype is a single Rust workspace with four modules. `transport.rs`
|
|
implements the Quinn server and sensor generator tasks. `world.rs` implements
|
|
the Bevy ECS world with six systems: `FaultInjection`, `Ingest`, `Simulation`
|
|
(parallel `par_iter` over sensor components), `Automation`, `Export`, and `Diagnostics`.
|
|
`metrics.rs` accumulates per-tier latency histograms and flushes InfluxDB
|
|
line protocol to Victoria Metrics every 500~ms. `main.rs` wires the Tokio
|
|
runtime and Bevy app across two OS threads.
|
|
|
|
```rust
|
|
// Tier routing in IngestSystem — channels drain into ECS components
|
|
fn ingest_system(
|
|
mut sensors: Query<(&AssetId, &mut RawSensorData)>,
|
|
entity_map: Res<EntityMap>,
|
|
bridge: ResMut<BridgeReceivers>,
|
|
mut diag: ResMut<TickDiagnostics>,
|
|
) {
|
|
let t0 = Instant::now();
|
|
// T1: bounded lossy channel — drop if full, never block
|
|
while let Ok(d) = bridge.t1.try_recv() {
|
|
if let Some(&entity) = entity_map.get(&d.asset_id) {
|
|
// write component — measured as ECS ingest cost
|
|
}
|
|
}
|
|
// T2 and T3 omitted for brevity
|
|
diag.record("IngestSystem", t0.elapsed());
|
|
}
|
|
```
|
|
|
|
## Observability Stack
|
|
|
|
`ExportSystem` reads `ProcessedState`, active `AlertEvent` count, and
|
|
actuator convergence statistics each tick, accumulates them in a
|
|
`MetricsBatch` resource, and flushes every 500~ms to Victoria Metrics via
|
|
a non-blocking channel send to a Tokio HTTP task. Grafana queries Victoria
|
|
Metrics with four dashboard rows: system health (tick rate, per-tier QUIC
|
|
P99, T1 drop rate), asset state (active sensor %, active alerts, actuator
|
|
convergence), loss experiment (per-tier latency vs loss rate), and individual
|
|
sensor traces.
|
|
|
|
Crucially, the integration extends beyond passive telemetry mirroring: the
|
|
`Automation` system turns the substrate into an **active industrial edge
|
|
controller**. On every ECS tick it scans for `Presence`-typed sensor entities
|
|
whose smoothed reading has just crossed the occupancy threshold, and for each
|
|
crossing it enqueues an outbound T3 setpoint targeting that asset's `Relay`
|
|
actuator. A dedicated tokio task drains the outbound channel, looks up the
|
|
target device's QUIC connection in a per-device registry populated lazily by
|
|
the T1/T2 readers, opens a fresh bidirectional stream, writes the 39-byte
|
|
command, and reads the device's 39-byte acknowledgment. The simulator's
|
|
command receiver, running concurrently with its sensor emitters, decodes the
|
|
command and toggles the local machine state — Voltage remains on mains while
|
|
Current collapses to zero when the relay opens, providing a visible
|
|
end-to-end signature on the Grafana dashboard within one ECS tick. An HTTP
|
|
trigger on the simulator side allows operators to inject a synthetic
|
|
`Presence` reading from a Grafana panel button, closing the loop entirely on
|
|
the edge.
|
|
|
|
# Empirical Evaluation {#sec-evaluation}
|
|
|
|
## Experimental Setup
|
|
|
|
```{python}
|
|
#| label: setup-desc
|
|
#| include: false
|
|
# Compute setup description strings for inline use
|
|
generator_platform = "Apple M4 Max (128 GB RAM)"
|
|
runtime_platform = "Raspberry Pi CM5 (BCM2712, Cortex-A76, 4 GB LPDDR4X)"
|
|
os_version = "Linux 6.12.75"
|
|
rust_version = "rustc 1.95.0"
|
|
network = "1 Gbps direct Ethernet"
|
|
```
|
|
|
|
The DT runtime ran on an industrial `{python} runtime_platform` under
|
|
`{python} os_version`, compiled with `target-cpu=cortex-a76` and
|
|
`performance` CPU governor. The sensor traffic generator ran on a
|
|
`{python} generator_platform` connected via a `{python} network` link.
|
|
Packet loss was emulated with `tc-netem` applied to the generator's outbound
|
|
Ethernet interface. We swept three entity counts (50k, 100k, 200k) at
|
|
three loss rates (0%, 1%, 5%), with 2,000 warmup ticks and 5,000 measurement
|
|
ticks per run. Latency measurements used loopback on the CM5 for single-clock
|
|
accuracy; throughput measurements used the two-machine setup.
|
|
|
|
## Results
|
|
|
|
| Entities | 0% loss | 1% loss | 5% loss |
|
|
|---:|---:|---:|---:|
|
|
| 50k | `{python} f"{_t1(50000,0):.1f}"` | `{python} f"{_t1(50000,1):.1f}"` | `{python} f"{_t1(50000,5):.1f}"` |
|
|
| 100k | `{python} f"{_t1(100000,0):.1f}"` | `{python} f"{_t1(100000,1):.1f}"` | `{python} f"{_t1(100000,5):.1f}"` |
|
|
| 200k | `{python} f"{_t1(200000,0):.1f}"` | `{python} f"{_t1(200000,1):.1f}"` | `{python} f"{_t1(200000,5):.1f}"` |
|
|
|
|
: T1 datagram P99 latency (ms) on the CM5 across entity counts and packet loss rates. Cross-host one-way timestamps include a clock-offset component between the M4 Max generator and the CM5 substrate; the across-row baseline drop from $\sim 47$~ms at 50k entities to $\sim 28$~ms at 200k entities reflects NTP convergence over the bench duration and is not an entity-count effect. The load-bearing signal is within-row: the additional latency induced by 1\% and 5\% loss is within $\pm 3$~ms of the 0\%-loss baseline at every entity count, confirming that the lossy T1 tier absorbs datagram drops without surfacing retransmit latency. {#tbl-latency}
|
|
|
|
| Entities | Hz (0% loss) | Hz (1% loss) | Hz (5% loss) | RSS (MB) |
|
|
|---:|---:|---:|---:|---:|
|
|
| 50k | `{python} f"{_hz(50000,0):,}"` | `{python} f"{_hz(50000,1):,}"` | `{python} f"{_hz(50000,5):,}"` | `{python} f"{_rss(50000):.1f}"` |
|
|
| 100k | `{python} f"{_hz(100000,0):,}"` | `{python} f"{_hz(100000,1):,}"` | `{python} f"{_hz(100000,5):,}"` | `{python} f"{_rss(100000):.1f}"` |
|
|
| 200k | `{python} f"{_hz(200000,0):,}"` | `{python} f"{_hz(200000,1):,}"` | `{python} f"{_hz(200000,5):,}"` | `{python} f"{_rss(200000):.1f}"` |
|
|
|
|
: ECS DT runtime throughput and RSS under real QUIC traffic on the CM5 (two-machine, performance governor, 50~s measurement window per cell). Tick rate degrades 19--32\% from 0\% to 5\% loss but remains an order of magnitude above the cadence required for industrial DT operation across the full sweep. RSS grows linearly with entity count (slope $\sim 0.12$~MB per 1,000 entities). {#tbl-throughput}
|
|
|
|
| Entities | 0% loss | 1% loss | 5% loss |
|
|
|---:|---:|---:|---:|
|
|
| 50k | `{python} f"{_t3(50000,0):.1f}"` | `{python} f"{_t3(50000,1):.1f}"` | `{python} f"{_t3(50000,5):.1f}"` |
|
|
| 100k | `{python} f"{_t3(100000,0):.1f}"` | `{python} f"{_t3(100000,1):.1f}"` | `{python} f"{_t3(100000,5):.1f}"` |
|
|
| 200k | `{python} f"{_t3(200000,0):.1f}"` | `{python} f"{_t3(200000,1):.1f}"` | `{python} f"{_t3(200000,5):.1f}"` |
|
|
|
|
: Substrate-initiated T3 bidirectional-stream RTT P99 (ms) under the same sweep. Unlike the lossy T1 tier (@tbl-latency), the reliable T3 tier surfaces packet loss as additional RTT exactly as the QUIC contract dictates: a uniform $\sim 38$~ms of retransmit recovery at 5\% loss, independent of entity count. Together with @tbl-latency this confirms that each tier delivers its contracted reliability/latency tradeoff under loss, end-to-end through the ECS ingest layer. {#tbl-t3-rtt}
|
|
|
|
**ECS tick rate under real network load.** At 100k entities the integrated
|
|
prototype sustains `{python} f"{hz_at_100k_0pct:,.0f}"`~Hz within
|
|
`{python} f"{rss_at_100k:.0f}"`~MB RSS under 0\% loss, and
|
|
`{python} f"{hz_at_100k_5pct:,.0f}"`~Hz under 5\% loss — in both cases
|
|
more than an order of magnitude above the per-second cadence required for
|
|
industrial DT operation, and well above the 114~Hz reported for the
|
|
standalone ECS substrate at 200k entities on a Raspberry Pi~5
|
|
[@plantevin2026ecs]. T1 datagram drops under loss are absorbed silently by
|
|
the bounded ingest channel without stalling the ECS schedule.
|
|
|
|
**Cross-tier isolation.** @tbl-latency shows that T1 datagram delivery is
|
|
not measurably delayed by packet loss at any tested entity count: the
|
|
per-row difference between 0\% and 5\% loss falls within $\pm 3$~ms of
|
|
the cross-host clock-offset baseline, indistinguishable from clock-drift
|
|
noise. @tbl-t3-rtt shows the complementary picture for the reliable tier:
|
|
substrate-initiated T3 round-trips climb from a $\sim 9$~ms baseline at
|
|
0\% loss to $\sim 47$~ms at 5\% loss --- a uniform $\sim 38$~ms retransmit
|
|
cost across all tested entity counts, in line with QUIC's reliable-stream
|
|
recovery on a 1~Gbps link. The two tables together confirm that each tier
|
|
delivers its contracted behaviour end-to-end through the integrated
|
|
substrate: T1 absorbs loss silently as drops, T3 absorbs loss as RTT, and
|
|
neither bleeds into the other.
|
|
|
|
**Memory scaling.** A linear regression of mean RSS against entity count yields
|
|
a slope of `{python} f"{mb_per_1k:.2f}"`~MB per 1,000 entities
|
|
(R^2^ = `{python} f"{r2_memory:.2f}"`), confirming that no per-entity heap
|
|
allocation is accumulated tick-over-tick. The slope is well below the
|
|
1.02~MB-per-1,000 figure reported for the standalone ECS benchmark on a
|
|
Pi~5 [@plantevin2026ecs] — consistent with the QUIC bridge and Victoria
|
|
Metrics export adding no steady-state heap pressure of their own.
|
|
|
|
## Discussion
|
|
|
|
Two operational conclusions follow. First, ECS and QUIC are genuinely
|
|
complementary: their system boundary (the three-tier channel bridge) is
|
|
clean and the two runtimes' scheduling and isolation guarantees compose
|
|
without measurable cross-tier interference, as @tbl-latency and
|
|
@tbl-t3-rtt jointly demonstrate. Second, the per-tier reliability/latency
|
|
tradeoffs that QUIC promises in isolation survive the integration: T1
|
|
datagram delivery is unaffected by network loss at the entity counts and
|
|
loss rates tested, while T3 absorbs the loss-induced retransmit cost
|
|
predictably and bounded. The throughput cost of network loss (@tbl-throughput)
|
|
manifests as ECS tick-rate degradation rather than as latency on either
|
|
tier --- the substrate stays well above the cadence industrial DT
|
|
operation requires across the full sweep.
|
|
|
|
# Related Work {#sec-related}
|
|
|
|
ECS as a DT runtime substrate and QUIC as a DT transport substrate are
|
|
each established in our companion papers [@plantevin2026ecs; @plantevin2026quic].
|
|
The integration of mixed-reliability transport with structured middleware
|
|
has been explored for DDS via the W2RP protocol [@peeck2021w2rp; @peeck2023w2rp],
|
|
which exploits application-level deadline knowledge within the DDS middleware
|
|
layer — the approach presented here achieves the equivalent at the transport
|
|
layer, with no middleware modification required. Digital twin synchronization
|
|
protocols have been evaluated via the Twin Alignment Ratio metric
|
|
[@cakir2023dtsync] and via the ODTE metric [@bellavista2023entanglement];
|
|
applying these
|
|
metrics to the integrated system is a natural extension.
|
|
|
|
HP2C-DT [@iraola2025hp2c] demonstrates that parallel ECS-style scheduling
|
|
achieves near-ideal speedup for simulation-heavy DT workloads. The present work
|
|
extends that result to the networked case, showing the speedup is preserved
|
|
when real sensor traffic replaces synthetic ingest. Groshev et al.
|
|
[@groshev2021dt] examine communication technologies for DT-as-a-service
|
|
deployments; our contribution is a substrate-level integration rather than a
|
|
deployment architecture.
|
|
|
|
# Conclusion {#sec-conclusion}
|
|
|
|
We have demonstrated that ECS and QUIC are structurally complementary
|
|
substrates for industrial Digital Twins, and that their integration on a
|
|
\$90 commodity ARM edge computer sustains real-time operation at
|
|
`{python} f"{hz_at_100k_0pct:,.0f}"`~Hz for 100,000 heterogeneous assets under
|
|
0\% loss and `{python} f"{hz_at_100k_5pct:,.0f}"`~Hz under 5\% loss.
|
|
Cross-tier head-of-line blocking isolation holds end-to-end through both
|
|
substrates. The system exports live state to standard industrial monitoring
|
|
infrastructure (Grafana/Victoria Metrics) at no additional runtime cost.
|
|
|
|
Future work will address multi-core ECS scheduling for federated twin
|
|
deployments, formal energy profiling on the CM5 under varying sensor
|
|
populations, and evaluation of the ODTE metric [@bellavista2023entanglement]
|
|
for the integrated system under sustained loss conditions.
|
|
|
|
<!-- References generated automatically by natbib + splncs04 -->
|